Back to Top

Fleming CompaniesFleming Electric

Arc Flash Studies

Arc Flash Studies

Arc Flash Hazard is a subject that is undergoing increased discussion and scrutiny in today’s safety conscious environment. The intent of the standards in this area is to provide an increased level of safety for the Electrical worker. Those involved in the design, implantation and evaluation of electrical distribution systems must have an understanding of Arc Flash Hazards and how to evaluate the hazards as well as minimize or mitigate the hazard to the electrical worker.

Why should Fleming Electric perform an Arc Flash Study for you? An Arc Flash study is not required by the NEC, but Arc Flash equipment warning labels are. If you do not have any Arc Flash labels now, you need to install them. Labels are included in our Arc Flash study.

An Arc Flash study may be required by the NFPA70E If your system falls outside the boundaries set for the NFPA70E PPE tables. Certified technicians provide calculated Arc Flash energy values and labels that will be a key part of your Electrical Safety training.

If your electrical personnel do not know what level of PPE is required for a task, as per NFPA70E, you need to inform them. We inform you of the required NFPA70E PPE level and provide a detailed Arc Flash label which can be placed on equipment.

Do you have improperly maintained or installed equipment that would cause the increase of Arc Flash Energy or increase the potential for a fault to occur? With Fleming Electric your system will be thoroughly analyzed as a part of the Arc Flash energy calculations.

The following are common areas of concern:

  • Circuit breaker trip settings
  • Using Motor Circuit Protectors “MCPs” as feeder breakers
  • Under-rated or improperly sized fuses and circuit breakers
  • Under-rated Motor Control Center “MCC” buss bracing
  • Under-rated MCC starters and feeder breakers
  • Under-rated Switchgear, Switchboards, and Panel boards 

So, why not let us give you a quote to perform a detailed study that will include the required labels, required level of PPE details, and suggestions on how to decrease the available Arc Flash energy?

Projects

Fleming Electric View Projects
Back to Top

Quote Request

Our company was built on service and building long-term relationships with our clients is top priority. If you need a service quote, please fill out the form below and someone will be in touch promptly.

Press & Media

Northwest Arkansas Office Wins Award

December 22, 2015

Contractors who participate in SWEPCO’s energy efficiency programs across Northwest Arkansas gathered Dec. 3 for an appreciation luncheon in Fayetteville. An earlier luncheon in Texarkana...

image description

Fleming Insider

Browse All Articles

How Does Retinal Scanning Work?

March 24, 2014
Developed in the 1980s, retinal scanning is one of the most well-known biometric technologies, but it is also one of the least deployed. Retinal scans map the unique patterns of a person’s retina. The...
Read More

Fleming Companies moves to Bentonville

February 14, 2013
Fleming Electric, Inc. and Fleming Network Services, Inc. recently moved to 3311 SW I Street, Bentonville, Arkansas. The companies specialize in commercial, institutional and industrial projects. Services range...
Read More
  • 1-800-748-1614
  • 501-847-3090